Freezing and drying inside the ice condenser (single-chamber method) on five heatable shelves, optionally with a fan
Condenser capacity: 16 kg
Condenser temperature: -55 °C
Controller | LSCplus |
Method | Single-chamber |
Max. number of shelves | 5 |
Shelf diameter | 200 mm |
Total shelf area | 0,155 m² |
Shelf temperature | -30 °C to +60 °C |
Freezing and drying inside the ice condenser (single-chamber method) on two heatable shelves with stoppering device, optionally with a fan
Condenser capacity: 16 kg
Condenser temperature: -55 °C
Controller | LSCplus |
Method | Single-chamber |
Max. number of shelves | 2 |
Shelf diameter | 250 mm |
Total shelf area | 0,09 m² |
Distance between shelves | 45 mm to 110 mm |
Max. capacity for 2R Vials | 300 |
Stoppering device | Yes |
Shelf temperature | -30 °C to +60 °C |
Two drying chambers with a total of 24 connections for round-bottom flasks, wide-neck bottles or ampoule distributors
Condenser capacity: 16 kg
Condenser temperature: -55 °C
Controller | LSCplus |
Method | Double-chamber |
Max. connections | 24 |
Drying manifold for eight round-bottom flasks, wide-neck bottles or ampoule distributors; specifically suitable for solvent drying
Condenser capacity: 16 kg
Condenser temperature: -55 °C
Controller | LSCplus |
Method | Double-chamber |
Max. connections | 8 |
Five heatable shelves, additional connections for twelve round-bottom flasks, wide-neck bottles or ampoule distributors
Condenser capacity: 16 kg
Condenser temperature: -55 °C
Controller | LSCplus |
Method | Double-chamber |
Max. number of shelves | 5 |
Shelf diameter | 200 mm |
Total shelf area | 0,155 m² |
Distance between shelves | 25 mm |
Max. connections | 12 |
Ten heatable shelves
Condenser capacity: 16 kg
Condenser temperature: -55 °C
Controller | LSCplus |
Method | Double-chamber |
Max. number of shelves | 10 |
Shelf diameter | 200 mm |
Total shelf area | 0,31 m² |
Distance between shelves | 25 mm |
Two heatable shelves with stoppering device, additional connections for twelve round-bottom flasks, wide-neck bottles or ampoule distributors
Condenser capacity: 16 kg
Condenser temperature: -55 °C
Controller | LSCplus |
Method | Double-chamber |
Max. number of shelves | 2 |
Shelf diameter | 250 mm |
Total shelf area | 0,09 m² |
Distance between shelves | 45 mm to 110 mm |
Max. capacity for 2R Vials | 300 |
Stoppering device | Yes |
Max. connections | 12 |
Four heatable shelves with stoppering device
Condenser capacity: 16 kg
Condenser temperature: -55 °C
Controller | LSCplus |
Method | Double-chamber |
Max. number of shelves | 4 |
Shelf diameter | 250 mm |
Total shelf area | 0,18 m² |
Distance between shelves | 45 mm to 110 mm |
Max. capacity for 2R Vials | 600 |
Stoppering device | Yes |
Eight heatable shelves; optional lifting device for drying chamber available
Condenser capacity: 16 kg
Condenser temperature: -55 °C
Controller | LSCplus |
Method | Double-chamber |
Max. number of shelves | 8 |
Shelf diameter | 375 mm |
Total shelf area | 0,88 m² |
Distance between shelves | 48 mm |
Compact tabletop unit for effective lyophilisation of specimens with innovative Wireless Shelf Technology. The freeze dryer can be configured with tried and tested accessories to meet your specific needs. The simple and intuitive LSCplus controller supports manual and automatic process control for reproducible results.
Two different drying methods are available to handle virtually every task. -55 °C condenser temperature for drying aqueous specimens.
Ice condenser capacity | 16 kg |
---|---|
Ice condenser performance | 12 kg/24 h |
Ice condenser temperature | -55 °C |
Dimensions of base model (W x H x D) | 860 x 485 x 650 mm |
Weight | 135 kg |
Communication port | Ethernet |